Split

Panasonic heat pump LT outdoor unit 400V WH-UD16HE8 heating / cooling 16KW

Order No.: 758.1869
Manufacturer number: WH-UD16HE8
Manufacturer: Panasonic

To subsequent product 758.3731

Loading

One click to the most important information:

Description

The new models of the H Generation from Panasonic have been specially developed for low energy buildings and achieve impressive COP values (above 5 for the 3.2 kW device). The new models of the H generation from Panasonic feature an entirely new hydromodule as well as a newly developed ...
The new models of the H Generation from Panasonic have been specially developed for low energy buildings and achieve impressive COP values (above 5 for the 3.2 kW device). The new models of the H generation from Panasonic feature an entirely new hydromodule as well as a newly developed regulator with a graphical backlit LCD display and touch keys. They have been specially developed for low energy buildings and achieve impressive COP values (above 5 for the 3 kW device). Thanks to the mature technology and advanced control, these devices guarantee excellent performance and energy efficiency at -7 °C and even down to -15 °C. They can be used with outside temperatures down to -20 °C.

show more


Features

  • Newly designed hydromodule with optimised access to electrical and hydraulic components, white coloured
  • Highly efficient with a COP value of 5 (3.2 kW device)
  • Highest energy efficiency rating currently possible (A++)
  • New heating regulator with graphical touch display
  • Optional additional board for ...
  • Newly designed hydromodule with optimised access to electrical and hydraulic components, white coloured
  • Highly efficient with a COP value of 5 (3.2 kW device)
  • Highest energy efficiency rating currently possible (A++)
  • New heating regulator with graphical touch display
  • Optional additional board for extended functionality: two mixed heating circuits, pool heating, bivalence control, solar thermal control, 0-10 V power control, smart grid inputs
  • Integrated vortex volumetric flow rate sensor for dynamically adapting the volumetric flow of the Panasonic high-efficiency pump
  • Integrated dirt filter with shut-off valves
  • Special software for low energy buildings with minimal input temperature of 20 °C (3-5 kW devices)
  • Optional 3-way switching valve set for installing in the hydromodule.

show more


Suitable products
Combi hydro module
Panasonic heat pump combi-hydromodule WH-ADC0916H9E8 heating / cooling 400V

Panasonic heat pump combi-hydromodule WH-ADC0916H9E8 heating / cooling 400V

Order No.: 758.1887
Hydro module
Panasonic heat pump LT hydromodule WH-SDC16H9E8 heating / cooling 16KW

Panasonic heat pump LT hydromodule WH-SDC16H9E8 heating / cooling 16KW

Order No.: 758.1866

Accessories / Replacement parts

  • 3-Wege-Umschaltventil-Set
    Panasonic heat pump tap water valve CZ-NV1 3-way-valve f. gen.H
    Order No.: 758.1849
  • Additional circuit board
    Panasonic heat pump additional circuit board CZ-NS4P Control function for generation H
    Order No.: 758.1850
  • Interface
    Panasonic heat pump communication system CZ-TAW1 interface control via internet
    Order No.: 758.1861
  • Magnetfilter
    Panasonic Magnetfilter Nachrüstsatz PAW-A2W-MGTFILTER für H-Generation
    Order No.: 758.2837
  • Memory
    Panasonic heat pump water reservoir 300 L stainless steel, without 3-way valve HE
    Order No.: 758.1891
  • Panasonic heat pump water reservoir 200L enamelled, without 3-way valve
    Order No.: 758.2649
  • Panasonic heat pump water reservoir 300L enamelled, without 3-way valve
    Order No.: 758.2650
  • Panasonic heat pump water reservoir 200 L stainless steel, without 3-way valve HE
    Order No.: 758.1889
  • Pufferspeicher
    Panasonic heat pump volume expansion PAW-BTANK50L-2 stainless steel
    Order No.: 758.2679
  • Raumthermostat
    Panasonic heat pump room thermostat PAW-A2W-RTWIRED cable, LCD/weekly timer
    Order No.: 758.1696
  • Panasonic heat pump room thermostat PAW-A2W-RTWIRELESS radio, LCD/weekly timer
    Order No.: 758.1697
  • Schallhaube
    Panasonic Protective cover Sound insulation system Heat pump PAW-A2W-HB4-SC heat pump for three-phase heat pump with 2 fans
    Order No.: 758.2654
  • Sichtschutzgehäuse
    Evolar Sichtschutz Gehäuse Tower Lamellen Anthrazit 1600x1200x650mm
    Order No.: 732.5001
  • Evolar Sichtschutz Gehäuse Tower Lamellen Weiss 1600x1200x650mm
    Order No.: 732.5002
  • Sound insulation set
    Panasonic heat pump sound insulation set CZ-UG30
    Order No.: 758.2508

Technical data

Dimensions
Width
900 mm
Height
1340 mm
Depth
320 mm
General information
Application
Heizen und Kühlen
Construction
Split
Energy efficiency­class
Heating
A+++
W35
 
A++
W55
Seasonal room heating energy efficiency
190 %
W35
 
130 %
W55
Refrigerant
R410A
Amount of refrigerant
2,55 kg
max. height difference
indoor unit/outdoor unit
20 m
max. pre-filled line length
10 m
zul. Leitungslänge
(min. - max.)
3 - 30 m
permissible filling quantity per meter
50 g/m
Electrical Data
Supply voltage
400/3/50 V/Ph/Hz
Weight
Weight net
107,0 kg
Performance data
COP
4,28
(A7/W35)
 
3,28
(A2/W35)
 
4,04
(A2/W35) Erläuterung 3
 
2,57
(A-7/W35)
EER
2,56
(A35/W7)
 
4,12
(A35/W18)
Nominal heating capacity
16,00 kW
bei (A7/W35)
13,00 kW bei (A2/W35)
6,22 kW bei (A2/W35) Erläuterung 3
11,40 kW bei (A-7/W35)
Nominal cooling capacity
12,20 kW
bei (A35/W7)
12,20 kW bei (A35/W18)
SCOP
4,82
W35
 
3,33
W55
Pipe connections
Liquid line
9,52 mm
3/8 inch
Suction gas line
15,88 mm
5/8 inch
Sound data
Sound power level
68,0 dB(A)
(A7/W35) Normal (Erläuterung 3)
Sound power level
Heating
68 dB(A)
(A7/W35) Normal (Explanation 3)
 
65 dB(A)
Part load (Explanation 4)
Temperature data
Betriebsbereich Außentemperatur
Heizen
-20 bis +35 °C
Kühlen
+16 bis +43 °C
Betriebsbereich Wasseraustrittstemperatur
Heizen
+20 bis +55 °C
Kühlen
+5 bis +20 °C

Notes:

  • The EER/COP values are calculated as defined in EN 14511.
  • Further data relating to ecological design can be found in the product data sheets.
  • Authorised service partners and installation companies can activate the cooling function via a special setting.
  •  These devices are not compatible with the HPM Heat Pump Manger (PAW-HPM1) and its accessories. Connectivity products must be compatible with the H Generation.

 

1) Models with a model number ending in “B” feature an additional circulating pump as well as a mixing valve for
directly connecting a second regulated heating circuit.
2) Values not available at time of printing.
3) Energy efficiency scale from A++ to G.
4) Energy efficiency rating including regulator. Energy efficiency scale from A+++ to D.
5) Energy efficiency scale from A to G.
6) 5 m spacing with quarter-circle shaped emission.

Technical modifications reserved. Product images may differ from the actual product and are meant for demonstration purposes only. Absolutely no liability can be assumed for possible indication errors and errors in the manufacturers’ information.
Loading

Login now for complete access

To login