- Products
- Panasonic heat pump LT outdoor unit 400V WH-UD16HE8 heating / cooling 16KW
Split
Panasonic heat pump LT outdoor unit 400V WH-UD16HE8 heating / cooling 16KW
Icon. Image similar to product.
Description
The new models of the H Generation from Panasonic have been specially developed for low energy buildings and achieve impressive COP values (above 5 for the 3.2 kW device). The new models of the H generation from Panasonic feature an entirely new hydromodule as well as a newly developed ...
The new models of the H Generation from Panasonic have been specially developed for low energy buildings and achieve impressive COP values (above 5 for the 3.2 kW device). The new models of the H generation from Panasonic feature an entirely new hydromodule as well as a newly developed regulator with a graphical backlit LCD display and touch keys. They have been specially developed for low energy buildings and achieve impressive COP values (above 5 for the 3 kW device). Thanks to the mature technology and advanced control, these devices guarantee excellent performance and energy efficiency at -7 °C and even down to -15 °C. They can be used with outside temperatures down to -20 °C.
Features
- Newly designed hydromodule with optimised access to electrical and hydraulic components, white coloured
- Highly efficient with a COP value of 5 (3.2 kW device)
- Highest energy efficiency rating currently possible (A++)
- New heating regulator with graphical touch display
- Optional additional board for ...
- Newly designed hydromodule with optimised access to electrical and hydraulic components, white coloured
- Highly efficient with a COP value of 5 (3.2 kW device)
- Highest energy efficiency rating currently possible (A++)
- New heating regulator with graphical touch display
- Optional additional board for extended functionality: two mixed heating circuits, pool heating, bivalence control, solar thermal control, 0-10 V power control, smart grid inputs
- Integrated vortex volumetric flow rate sensor for dynamically adapting the volumetric flow of the Panasonic high-efficiency pump
- Integrated dirt filter with shut-off valves
- Special software for low energy buildings with minimal input temperature of 20 °C (3-5 kW devices)
- Optional 3-way switching valve set for installing in the hydromodule.
Suitable products
Accessories / Replacement parts
-
3-Wege-Umschaltventil-Set
-
3-way valve
-
Additional circuit board
-
Anschluss-Montagesatz für Kombi-Hydromodule
-
Interface
-
Magnetfilter
-
Memory
-
Pufferspeicher
-
Raumthermostat
-
Schallhaube
-
Sichtschutzgehäuse
-
Sound insulation set
Technical data
Dimensions
Width
900 mm
Height
1340 mm
Depth
320 mm
General information
Application
Heizen und Kühlen
Construction
Split
Energy efficiencyclass
Heating
A+++
W35
A++
W55
Seasonal room heating energy efficiency
190 %
W35
130 %
W55
Refrigerant
R410A
Amount of refrigerant
2,55 kg
max. height difference
indoor unit/outdoor unit
20 m
max. pre-filled line length
10 m
zul. Leitungslänge
(min. - max.)
(min. - max.)
3 - 30 m
permissible filling quantity per meter
50 g/m
Electrical Data
Supply voltage
400/3/50 V/Ph/Hz
Weight
Weight net
107,0 kg
Performance data
COP
4,28
(A7/W35)
3,28
(A2/W35)
4,04
(A2/W35) Erläuterung 3
2,57
(A-7/W35)
EER
2,56
(A35/W7)
4,12
(A35/W18)
Nominal heating capacity
16,00 kW
bei (A7/W35)
13,00 kW bei (A2/W35)
6,22 kW bei (A2/W35) Erläuterung 3
11,40 kW bei (A-7/W35)
13,00 kW bei (A2/W35)
6,22 kW bei (A2/W35) Erläuterung 3
11,40 kW bei (A-7/W35)
Nominal cooling capacity
12,20 kW
bei (A35/W7)
12,20 kW bei (A35/W18)
12,20 kW bei (A35/W18)
SCOP
4,82
W35
3,33
W55
Pipe connections
Liquid line
9,52 mm
3/8 inch
Suction gas line
15,88 mm
5/8 inch
Sound data
Sound power level
68,0 dB(A)
(A7/W35) Normal (Erläuterung 3)
Sound power level
Heating
68 dB(A)
(A7/W35) Normal (Explanation 3)
65 dB(A)
Part load (Explanation 4)
Temperature data
Betriebsbereich Außentemperatur
Heizen
-20 bis +35 °C
Kühlen
+16 bis +43 °C
Betriebsbereich Wasseraustrittstemperatur
Heizen
+20 bis +55 °C
Kühlen
+5 bis +20 °C
Notes:
- The EER/COP values are calculated as defined in EN 14511.
- Further data relating to ecological design can be found in the product data sheets.
- Authorised service partners and installation companies can activate the cooling function via a special setting.
- These devices are not compatible with the HPM Heat Pump Manger (PAW-HPM1) and its accessories. Connectivity products must be compatible with the H Generation.
1) Models with a model number ending in “B” feature an additional circulating pump as well as a mixing valve for
directly connecting a second regulated heating circuit.
2) Values not available at time of printing.
3) Energy efficiency scale from A++ to G.
4) Energy efficiency rating including regulator. Energy efficiency scale from A+++ to D.
5) Energy efficiency scale from A to G.
6) 5 m spacing with quarter-circle shaped emission.
Technical modifications reserved. Product images may differ from the actual product and are meant for demonstration purposes only. Absolutely no liability can be assumed for possible indication errors and errors in the manufacturers’ information.
Customers also bought...
Loading
Loading