- Products
- Heat pumps
- Outdoor units
- Split
- Panasonic heat pump T-CAP outdoor unit WH-UX12HE8 heating/cooling 12KW 400V
Split
Panasonic heat pump T-CAP outdoor unit WH-UX12HE8 heating/cooling 12KW 400V
Icon. Image similar to product.
Description
The new models of the H Generation can deliver their full rated power even at outdoor temperatures down to -20 °C without requiring an electrical heating element. The new T-CAP models of the H generation from Panasonic feature an entirely new hydromodule as well as a newly developed regulator ...
The new models of the H Generation can deliver their full rated power even at outdoor temperatures down to -20 °C without requiring an electrical heating element. The new T-CAP models of the H generation from Panasonic feature an entirely new hydromodule as well as a newly developed regulator with a graphical backlit LCD display and touch keys. Thanks to the mature technology and advanced control, these devices can deliver almost top heating performance and energy efficiency even at -20 °C without the need of an electrical heating element and can used with outside temperatures down to -28 °C. This provides plenty of safety when planning to use these heating systems even in the coldest regions. The new additional low noise SQ models also allow operation in noise sensitive environments.
Features
- Newly designed hydromodule with optimised access to electrical and hydraulic components, white coloured
- New series of quiet SQ models for use in noise-sensitive environments
- Highest energy efficiency rating currently possible (A++)
- New heating regulator with graphical touch display
- Optional ...
- Newly designed hydromodule with optimised access to electrical and hydraulic components, white coloured
- New series of quiet SQ models for use in noise-sensitive environments
- Highest energy efficiency rating currently possible (A++)
- New heating regulator with graphical touch display
- Optional additional board for extended functionality: two mixed heating circuits, pool heating, bivalence control, solar thermal control, 0-10 V power control, smart grid inputs
- Integrated vortex volumetric flow rate sensor for dynamically adapting the volumetric flow of the Panasonic high-efficiency pump
- Integrated dirt filter with shut-off valves
- Optional 3-way switching valve set for installing in the hydromodule.
Suitable products
Accessories / Replacement parts
-
3-Wege-Umschaltventil-Set
-
Additional circuit board
-
Interface
-
Magnetfilter
-
Memory
-
Pufferspeicher
-
Raumthermostat
-
Schallhaube
-
Sichtschutzgehäuse
-
Sound insulation set
Technical data
Dimensions
Width
900 mm
Height
1340 mm
Depth
320 mm
General information
Application
Heizen und Kühlen
Construction
Split
Energy efficiency
A+++
at 35°C
A++
at 55°C
Energy efficiencyclass
Heating
A++
W55
Seasonal room heating energy efficiency
170 %
W35
130 %
W55
Refrigerant
R410A
Amount of refrigerant
2,85 kg
max. height difference
indoor unit/outdoor unit
20 m
max. pre-filled line length
10 m
zul. Leitungslänge
(min. - max.)
(min. - max.)
3 - 30 m
permissible filling quantity per meter
50 g/m
Electrical Data
Supply voltage
400/3/50 V/Ph/Hz
Weight
Weight net
108,0 kg
Performance data
COP
4,74
(A7/W35)
3,44
(A2/W35)
2,72
(A-7/W35)
EER
2,81
(A35/W7)
5,13
(A35/W18)
Nominal heating capacity
12,00 kW
bei (A7/W35)
12,00 kW bei (A2/W35)
12,00 kW bei (A-7/W35)
12,00 kW bei (A2/W35)
12,00 kW bei (A-7/W35)
Nominal cooling capacity
10,00 kW
bei (A35/W7)
10,00 kW bei (A35/W18)
10,00 kW bei (A35/W18)
SCOP
4,33
W35
3,33
W55
Pipe connections
Liquid line
9,52 mm
3/8 inch
Suction gas line
15,88 mm
5/8 inch
Sound data
Sound power level
59,0 dB(A)
(A7/W35) Flüster 3 (Erläuterung 2)
Sound power level
Heating
62 dB(A)
(A7/W35) Normal (Explanation 2)
59 dB(A)
(A7/W35) Whisper 3 (Explanation 2)
65 dB(A)
(A7/W55) Partial Load (Explanation 3)
Temperature data
Betriebsbereich Außentemperatur
Heizen
-28 bis +35 °C
Kühlen
+16 bis +43 °C
Betriebsbereich Wasseraustrittstemperatur
Heizen
+20 bis +60 °C
Kühlen
+5 bis +20 °C
Notes:
- The EER/COP values are calculated as defined in EN 14511.
- Further data relating to ecological design can be found in the product data sheets.
- Authorised service partners and installation companies can activate the cooling function via a special setting.
- These devices are not compatible with the HPM Heat Pump Manger (PAW-HPM1) and its accessories. Connectivity products must be compatible with the H Generation.
- Performance and noise data according to test reports. EHPA seal of approval pending
- Values not available at the time of printing.
- Noise data according to EHPA test reports.
- Outdoor temperature to down -10 °C with downward trending inlet temperature at 55 °C from an outdoor temperature of -15 °C
- Energy efficiency scale from A++ to G
- Energy efficiency rating including regulator. Energy efficiency scale from A+++ to D.
- Energy efficiency scale from A to G.
- 5 m spacing with quarter-circle shaped emission.
Technical modifications reserved. Product images may differ from the actual product and are meant for demonstration purposes only. Absolutely no liability can be assumed for possible indication errors and errors in the manufacturers’ information.
Loading
Loading