Hydro module

Panasonic heat pump LT combi-hydromodule WH-ADC0309J3E5 heating / cooling 230V

Order No.: 758.2571
Manufacturer number: WH-ADC0309J3E5
Manufacturer: Panasonic

One click to the most important information:

Description

The AQUAREA air / water heat pump series is the widest on the market and ensures that suitable systems are available for a wide range of heating and cooling requirements. With the new J generation, Panasonic now combines the proven AQUAREA advantages with the advantages of more environmentally ...

The AQUAREA air / water heat pump series is the widest on the market and ensures that suitable systems are available for a wide range of heating and cooling requirements. With the new J generation, Panasonic now combines the proven AQUAREA advantages with the advantages of more environmentally friendly refrigerant R32

Combi hydromodule standard version (1 heating circuit)

show more


Features

  • Top COP value of 5.33 (3 kW model)
  • Low installation costs
  • Easy installation thanks to hydraulic piping on the underside
  • Short installation time and minimisation of installation errors
  • Easy configuration of the controller
  • Small footprint
  • Electrical connections on the front
  • Easy maintenance and ...
  • Top COP value of 5.33 (3 kW model)
  • Low installation costs
  • Easy installation thanks to hydraulic piping on the underside
  • Short installation time and minimisation of installation errors
  • Easy configuration of the controller
  • Small footprint
  • Electrical connections on the front
  • Easy maintenance and assembly
  • Additional operating functions: The cooling function can be activated via a setting. This setting must be carried out by a service partner.
     

show more


Suitable products
3 kW Außengerät LT
Panasonic heat pump LT outdoor unit 230V WH-UD03JE5 heating / cooling 3.2kW

Panasonic heat pump LT outdoor unit 230V WH-UD03JE5 heating / cooling 3.2kW

Order No.: 758.2227
5 kW Außengerät LT
Panasonic heat pump LT outdoor unit 230V WH-UD05JE5 heating / cooling 5.0kW

Panasonic heat pump LT outdoor unit 230V WH-UD05JE5 heating / cooling 5.0kW

Order No.: 758.2228
7 kW Außengerät LT
Panasonic heat pump LT outdoor unit 230V WH-UD07JE5 heating / cooling 7.0 kW

Panasonic heat pump LT outdoor unit 230V WH-UD07JE5 heating / cooling 7.0 kW

Order No.: 758.2229
9 kW outdoor unit LT
Panasonic heat pump LT outdoor unit 230V WH-UD09JE5-1 heating / cooling 9.0 kW

Panasonic heat pump LT outdoor unit 230V WH-UD09JE5-1 heating / cooling 9.0 kW

Order No.: 758.2259

Accessories / Replacement parts

  • Additional circuit board
    Panasonic heat pump additional circuit board CZ-NS4P Control function for generation H
    Order No.: 758.1850
  • Raumthermostat
    Panasonic heat pump room thermostat PAW-A2W-RTWIRED cable, LCD/weekly timer
    Order No.: 758.1696
  • Panasonic heat pump room thermostat PAW-A2W-RTWIRELESS radio, LCD/weekly timer
    Order No.: 758.1697

Technical data

Dimensions
Width
598 mm
Height
1800 mm
Depth
717 mm
General information
Application
Heizen und Kühlen
Construction
Kombi-Hydromodul
Container volume
185 l
Energy efficiency
Room heating
A+++
bei 35°C Vorlauftemperatur
Refrigerant
R32
Material
Rostfreier Stahl
Electrical Data
Leistung E-Heizstab
3,00 kW
Supply voltage
230/1/50 V/Ph/Hz
Weight
Weight net
122,0 kg
Performance data
Hocheffizienzpumpe
Leistungsaufnahme
30 bis 120 W
Pumpenregelung
variabel
SCOP
3,30
Water heating energy efficiency (ERP)
A+
Wasservolumenstrom
9,20 l/min
with AG WH-UD03JE5 at (A7/W35)
 
14,30 l/min
with AG WH-UD05JE5 at (A7/W35)
 
20,10 l/min
with AG WH-UD07JE5 at (A7/W35)
 
25,80 l/min
with AG WH-UD09JE5-1 at (A7/W35)
Pipe connections
Wasserseitiger-Anschluss
Heizen
R 1 1/3 Inch
Wasserseitiger-Anschluß
Warmwasser
3/4 Inch
Sound data
Sound pressure level
Heating (high)
28 dB(A)
explanation 1
Cooling (high)
28 dB(A)
explanation 1
Temperature data
Betriebsbereich Außentemperatur
Heizen
-20 bis +35 °C
Kühlen
+10 bis +43 °C
max. water temperature
65 °C
Detaillierte technische Daten und die Leistungsangaben in Abhängigkeit von der Innengeräte-Außengeräte-Kombination finden Sie in den Ausschreibungstexten in der Rubrik Downloads!
 