- Products
- Mitsubishi air conditioner outdoor unit M-Series/City Multi PUMY-SP140 YKM
two pipe system
Mitsubishi air conditioner outdoor unit M-Series/City Multi PUMY-SP140 YKM
Icon. Image similar to product.
Order No.: 719.4699
Manufacturer number: PUMY-SP140YKM
Manufacturer: Mitsubishi
To subsequent product 719.5254
Loading
One click to the most important information:
Description
The multi-split systems of the PUMY series can operate in either cooling or heating mode. At least 2 indoor units must be connected.
PAC-MK33 / 53 connection boxes required
PAC-MK33 / 53 connection boxes required
Features
- Wifi-Cloud
- Automatic restart after power failure
- Pre-filled with refrigerant R410A
- Can heat during low temperatures
- Can cool during low temperatures
Scope of delivery
- 1x Mitsubishi Klima Außengerät M-Ser/CityM PUMY-SP140 YKM
Suitable products
Accessories / Replacement parts
-
Air guide plate
-
Condensate drainage
-
Wind guard
Technical data
Dimensions
Width
1050 mm
Height
981 mm
Depth
370 mm
zul. Leitungslänge pro Innengerät
95 m
General information
Connectable indoor units
2 bis 8
type 15 to 100
Application
Kühlen und Heizen
Type
VRF
Construction
Außengerät
Refrigerant
R410A
Refrigerant GWP
2088
Amount of refrigerant
3,5 kg
max. height difference
indoor unit/outdoor unit
15 m
explanation 1
zul. Leitungslänge
(min. - max.)
(min. - max.)
120 m
Electrical Data
Recommended overcurrent relay
16 A
Nennbetriebsstrom
Heizen
7,15 A
Kühlen
7,23 A
Supply voltage
400/3/50 V/Ph/Hz
Weight
Weight net
94,0 kg
Performance data
COP
4,1
EER
3,30
Air volume
4820 m³/h
Nominal heating capacity
16,50 kW
Nominal cooling capacity
15,50 kW
Nominal power consumption
Heating
4,02 kW
Cooling
4,70 kW
Pipe connections
Liquid line
10 mm
explanation 2
Gas line
16 mm
explanation 3
Sound data
Sound pressure level
Heating
56,0 dB(A)
Schalldruckpegel
Kühlen
54,0 dB(A)
Temperature data
Außentemperatur-Grenzwerte
Heizen
-20 bis +15 °C
Kühlen
-5 bis +46 °C
Notes
1) Value can deviate with distributor
2) Connections to indoor units with connection box Ø (mm) of fluid line: 3 x 6 to 5 x 6
3) Connections to indoor units with connection box Ø (mm) of gas line: 3 x 10 to 4 x 10 + 1 x 12
Our air conditioning systems and heat pumps contain fluorinated greenhouses gases R410A, R407C, R134a, R32.
The multi-split systems of the PUMY series can operate in either cooling or heating mode.
At least 2 indoor units must be connected.
PAK-MK33/53 connection boxes required
Further information can be found in the respective operating manual.
Technical modifications reserved. Product images may differ from the actual product and are meant for demonstration purposes only. Absolutely no liability can be assumed for possible indication errors and errors in the manufacturers’ information.
Customers also bought...
Loading
Loading