- Products
- Air conditioners & ventilation systems
- Air conditioners
- VRF
- Indoor units
- Floor mounted units
- Mitsubishi air conditioner City Multi indoor standing unit PFFY-P63 VCM-E without cladding
Mitsubishi air conditioner City Multi indoor standing unit PFFY-P63 VCM-E without cladding
More in this category: Floor mounted units
One click to the most important information:
Description
Optionally available without cladding so that this ultra-modern air conditioning unit can be made to blend seamlessly into the room architecture. At just 200 mm deep, these units can be installed in the peripheries of rooms and provide top performance.
Furthermore, the chest units feature a ...
?xml>Optionally available without cladding so that this ultra-modern air conditioning unit can be made to blend seamlessly into the room architecture. At just 200 mm deep, these units can be installed in the peripheries of rooms and provide top performance.
Furthermore, the chest units feature a dehumidifier function that stabilises the humidity in the room as the temperature changes. Further cooling is prevented and the air dehumidified in order to keep it fresh and invigorating.
DIP switches on the unit allow you to choose from four different pressures. This allows the device to be adapted for different installation situations.
The DC fan motors ensure very efficient operation at high pressure and with low noise.
Features
- Microprocessor control for monitoring target temperature in cooling mode from 19 °C to 30 °C, in heating mode from 17 °C to 28 °C. Automatic switching between heating/cooling (R2 systems only or using optional TG2000 software with G50 central remote control).
- Special program for ...
- Microprocessor control for monitoring target temperature in cooling mode from 19 °C to 30 °C, in heating mode from 17 °C to 28 °C. Automatic switching between heating/cooling (R2 systems only or using optional TG2000 software with G50 central remote control).
- Special program for dehumidifying room air. All values entered are saved in the event of power failure.
- Automatic restart after power failure, temperature adjustment in heating mode, air outlet direction can be adjusted in cooling mode, lock or release the slats, autostart for indoor units when power supply active, external static pressure can be selected via DIP switch.
- Timer control. Fault diagnostics system with fault memory. In the event of a fault, the unit is immediately shut off and an error code is displayed on the remote control.
- The LEV valve is closed via the voltage bus to protect against ice formation.
- Faults in other devices in the system are shown on the remote control and indicate the device number (address).
- Monitoring and control of the integrated electronic injection valve (LEV) along the MSS curve in order to achieve optimum efficiency for the heat exchanger in all operating states.
- Three thermistors form a 3-point regulating circuit for precisely maintaining the set room temperature.
- Monitoring of evaporator surface temperature with protection against ice formation.
- Testing and emergency operation programs.
Accessories / Replacement parts
-
Signal transmission booster
-
Adapter for ingoing signals
-
Adapter for outgoing signals
-
BACnet™-Interface-Module
-
Cable remote control
-
Central system control
-
External ambient temperature sensor
-
Group remote control
-
Infrared receiver unit
-
Infrared remote control
-
Interface box
-
LonWorks®-Interface
-
Mel-Cloud WiFi-Adapter
Technical data
(Niedrig/Mittel/Hoch)
(Niedrig/Mittel/Hoch)