Concealed duct installation units

Mitsubishi air conditioner City Multi concealed duct unit PEFY-P71 VMHS-E

Mitsubishi Electric Logo
Order No.: 719.4756
Manufacturer number: PEFY-P71VMHS-E
Manufacturer: Mitsubishi

To previous product 719.2135

More in this category: Concealed duct installation units

Loading

One click to the most important information:

Description

10 models with cooling capacity from 4.5 to 28.0 kW means there is an ideal device for every application. If long air ducts are to be installed, then the PEFY-VMH duct installation units with static pressure of 50 to 250 Pa are what you need. Components that need servicing such as fan rollers ...

10 models with cooling capacity from 4.5 to 28.0 kW means there is an ideal device for every application. If long air ducts are to be installed, then the PEFY-VMH duct installation units with static pressure of 50 to 250 Pa are what you need. Components that need servicing such as fan rollers and fan motors are accessible via a servicing opening.

show more


Features

  • Top flexibility
  • High pressure
  • Excellent serviceability
  • Optional condensate pump

Accessories / Replacement parts

  • Accessories/replacement parts
    Mitsubishi Long-Life filter element PAC-KE88LAF
    Order No.: 719.2236

Technical data

Dimensions
Width
1030 mm
Height
380 mm
Depth
900 mm
General information
Application
Kühlen und Heizen
Type
VRF
Construction
Kanalgerät
Refrigerant
R410A
Pressure
Static pressure
50 / 100 / 150 / 200 Pa
Siehe Erläuterung 2
Electrical Data
Supply voltage
230/1/50 V/Ph/Hz
max. operating current
0,52 A
Weight
Weight net
45,0 kg
Performance data
Air volume (low/medium/high)
930 / 960 / 1320 m³/h
Nominal heating capacity
9,00 kW
Nominal cooling capacity
8,00 kW
Nominal power consumption
Heating
0,075 kW
Cooling
0,075 kW
Pipe connections
Liquid line
10 mm
Gas line
16
Sound data
Schalldruckpegel
Heizen
(Niedrig/Mittel/Hoch)
24 / 26 / 30 dB(A)
Kühlen
(Niedrig/Mittel/Hoch)
24 / 26 / 30 dB(A)
Schalldruckpegel
(Niedrig/Mittel/Hoch)
24 / 26 / 30 dB(A)
Siehe Erläuterung 1

Notes

  1. Acoustic pressure level measured centrally at 1.5 m below the unit with 50 Pa external static pressure
  2. Static pressure is set via a DIP switch
     

Our air conditioning systems and heat pumps contain R410A, R407C, R134a, R32 fluorinated greenhouses gases.
Further information can be found in the respective operating manual.

Technical modifications reserved. Product images may differ from the actual product and are meant for demonstration purposes only. Absolutely no liability can be assumed for possible indication errors and errors in the manufacturers’ information.