Description

The sturdy steel housing is self-supporting and features an electrostatically applied polyester coating for optimal protection against corrosion. A set of vibration dampers is also included.

2 indoor units (min. 2) can be connected to this outdoor unit. The power of each individual indoor unit ...

The sturdy steel housing is self-supporting and features an electrostatically applied polyester coating for optimal protection against corrosion. A set of vibration dampers is also included.

2 indoor units (min. 2) can be connected to this outdoor unit. The power of each individual indoor unit must not exceed 3.5 kW. Maximum rated cooling capacity (sum of the indoor units) must not be more than 6.1 kW (index 21). If connecting more than 100%, the cooling capacity increase is no longer linear. Simultaneous cooling and heating with different indoor units is not possible.

show more


Features

  • Aktive Energiekontrolle
  • Energieanzeige
  • 2-Wege Swing
  • Schnelles Heizen
  • Dualer Schutzfilter
  • Auto Reinigung
  • Komfort Luft
  • Schnelle & einfache Installation
  • Intelligente Diagnose

Scope of delivery

  • 1x LG Klima Außengerät Multi-Split MU2R15.U13

Technical data

Dimensions
Width
770 mm
Height
545 mm
Depth
288 mm
General information
Connectable indoor units
2
Application
Kühlen und Heizen
Type
Multi-Split
Construction
Außengerät
Refrigerant
R32
Amount of refrigerant
1,0 kg
max. height difference
indoor unit/outdoor unit
15 m
Electrical Data
Recommended overcurrent relay
13 A
Connection cable
4 x 0,75 mm²
Supply voltage
230/1/50 V/Ph/Hz
empfohlener Netzkabel­querschnitt
3 x 2,5 mm²
Weight
Circa
32,5 kg
Performance data
Air volume
Heating (high)
 
Cooling (high)
 
Nominal heating capacity
4,70 kW
Nominal cooling capacity
4,10 kW
Pipe connections
Liquid line
6.35 mm
 
1/4 inch
Gas line
9.52 mm
 
3/8 inch
Sound data
Sound pressure level
Heating (high)
48 dB(A)
Cooling (high)
45 dB(A)
Sound power
Cooling (high)
60 dB(A)
Temperature data
Außentemperatur-­Grenzwerte
Heizen
-15 bis +18 °C
Kühlen
-10 bis +48 °C

​​​​​​Erläuterungen:

  1. Die Leistungsangaben basieren auf folgenden Bedingungen:
    Kühlbetrieb: Innentemperatur 27°C TK / 19°C FK, Außentemperatur 35°C TK / 24°C FK
    Heizbetrieb: Innentemperatur 20°C TK / 15°C FK, Außentemperatur 7°C TK / 6°C FK; Verbindungsrohrlänge: 7,5m, Höhenunterschied: 0m
  2. Leistungen geprüft nach EN14511
  3. Schalldruckpegel gemessen nach DIN EN ISO 3745 im Abstand von 1m und in einer Höhe von 1,5m
  4. Schallleistungspegel gemessen nach DIN EN ISO 3741
  5. Die Dimensionierung der Elektroleitung und der Absicherung muss den jeweiligen örtlichen und nationalen gesetzlichen Vorschriften entsprechen.
     
  • Dieses Produkt enthält fluorierte Treibhausgase (R32)