Cassette units

Panasonic air conditioner PACi 4W cassette without cover PU S-140PU2E5B 14kW (840x840mm)

Order No.: 758.2181
Manufacturer number: S-140PU2E5B
Manufacturer: Panasonic

To previous product 758.2108

More in this category: Cassette units

Loading

One click to the most important information:

Description

The PU2 four-way cassette (90 x 90) sets new standards for energy-efficient operation and healthy and pleasant air. This has been possible thanks to the new design of the unit with more efficient and quieter fans and Nanoe™ X air purification. (Optionally available)

This item does not ...

The PU2 four-way cassette (90 x 90) sets new standards for energy-efficient operation and healthy and pleasant air. This has been possible thanks to the new design of the unit with more efficient and quieter fans and Nanoe™ X air purification. (Optionally available)

This item does not include a ceiling panel cover

show more


Features

  • Ceiling height up to 5.0 m
  • Condensate pump for delivery head up to 850 mm
  • Optional CZ-KPU3A cover with Econavi function as well as activity detection and revolving operation
  • Optional nanoe™ X air purification feature specially for commercial air conditioning systems
  • DC fan with turbo rotor: ...
  • Ceiling height up to 5.0 m
  • Condensate pump for delivery head up to 850 mm
  • Optional CZ-KPU3A cover with Econavi function as well as activity detection and revolving operation
  • Optional nanoe™ X air purification feature specially for commercial air conditioning systems
  • DC fan with turbo rotor: efficiency and quiet
  • Individual air guide slat control
  • For use in dual, trio and quattro systems there are additional models to those listed here with a power rating of 4.5 kW (see Panasonic price list from page 46).

    230 V version on request: U-100PZH2E5 758.2209 U-125PZH2E5 U-140PZH2E5

show more


Suitable products
Outdoor unit
Panasonic air conditioner outdoor unit PACi elite PE U-140PE1E8A 14KW 400V R410A

Panasonic air conditioner outdoor unit PACi elite PE U-140PE1E8A 14KW 400V R410A

Order No.: 758.1248

Accessories / Replacement parts

  • Cable remote control
    Panasonic cable remote control PACi/ECOi CZ-RTC5B design cable remote control
    Order No.: 758.2554
  • Ceiling panel
    Panasonic panel f. 4-W cassette CZ-KPU3 without ECONAVI 33.5x950x950mm
    Order No.: 758.1876
  • Panasonic panel f. 4-W cassette CZ-KPU3A with ECONAVI 33.5x950x950mm
    Order No.: 758.1877
  • Hotel remote control
    Panasonic cable remote control PACi/ECOi CZ-RE2C2 hotel remote control
    Order No.: 758.1561
  • Infrared remote control
    Panasonic receiver infrared f. 4W cassette unit CZ-RWSU3 f. cassettes MU2/PU2
    Order No.: 758.1719
  • Installation kit
    Panasonic NanoeTMX air cleaning ECOi/PACi option for MU2/PU2 4w-cassette
    Order No.: 758.2574
  • WLAN interface
    Panasonic WLAN adapter for ECOi/PACi CZ-CAPWFC1
    Order No.: 758.2612

Technical data

Dimensions
Width
840 mm
Height
319 mm
Depth
840 mm
Weight
Weight net
25 kg
Performance data
Design load
Heating
14,0 kW
at -10 °C
Cooling
14,0 kW
Dehumidification
6,0 l/h
Delivery head of condensate pump
850 mm
explanation 4
Luftmenge
Heizen
(Niedrig/Mittel/Hoch)
1200 / 1740 / 2280 m³/h
Kühlen
(Niedrig/Mittel/Hoch)
1200 / 1740 / 2280 m³/h
Nominal heating capacity
16,0 kW
Nominal cooling capacity
14,0 kW
Nominal power consumption
Heating
3,72 kW
Cooling
4,24 kW
SCOP
3,9
explanation 1
SEER
6,50
explanation 1
Sound data
Schalldruckpegel
Heizen
(Niedrig/Mittel/Hoch)
34 / 40 / 47 dB(A)
explanation 3
Kühlen
(Niedrig/Mittel/Hoch)
34 / 40 / 47 dB(A)
explanation 3
Schallleistung
Heizen
(Niedrig/Mittel/Hoch)
49 / 55 / 62 dB(A)
Kühlen
(Niedrig/Mittel/Hoch)
49 / 55 / 62 dB(A)

Notes

1) SEER/SCOP values are calculated according to EU Regulation 626/2011 for models with a rated power up to 12 kW and EU Regulation 2281/2016 for models with a rated power above 12 kW.
2) The annual power consumption is based on the standards in EU Regulation 626/2011.
3) Measurement locations: Indoor unit: 1.5 below the ceiling, centrally beneath the unit. Outdoor unit: 1 m in front of the device at a height of 1.5 m. The measured values are based on EUROVENT document 6/C/006-97.
4) Measured from lower edge of ceiling.