- Products
- Forstner domestic water heater 028-BE 280L (2WT) incl. insulation
Forstner domestic water heater 028-BE 280L (2WT) incl. insulation






One click to the most important information:
Description
Anyone operating a refrigeration system can enjoy a highly effective way to save energy. A refrigeration system removes heat from the items being cooled. In order not to lose this heat together with the machine heat uselessly to the environment, FRIONIC has been developed, which uses this heat ...
Anyone operating a refrigeration system can enjoy a highly effective way to save energy. A refrigeration system removes heat from the items being cooled. In order not to lose this heat together with the machine heat uselessly to the environment, FRIONIC has been developed, which uses this heat physically optimally.
Hot water and heating for free
Sensitive goods are usually stored chilled or frozen. A certain amount of energy must be used for cooling. This energy removes heat from the item being cooled, which is then simply dissipated into the atmosphere. Heat recovery makes use of the heat removed during the cooling process. FRIONIC converts this waste heat into valuable, free energy that can be directly used to heat process water and produce hot water.
Heating by cooling - heat from the refrigeration system
A heat exchanger matched to the power of the compressor is installed vertically into the reservoir. In the upper area of the heat exchanger, superheat is passed into the water. This generates water temperatures far above the condensation temperature. This means: A high water temperature - low pressure in the compressor - low energy consumption. In the middle area of the heat exchanger, condensation heat is given off to the heating water. In the lower area of the heat exchanger, the cooler water works to supercool the refrigerant and thus improve cooling capacity.
Hygienic process water heating using the throughflow principle
Overlaid stainless steel corrugated pipes provide hygienic heating for fresh water. The corrugated pipe (process water / hygiene boiler) has a spiral shape designed according to physical principles that is ideal for exchanging heat. Process water heating is linear from the cool to the hot area of the reservoir so that the hottest layer of water keeps being renewed. You will always have hot water available, even when the system is under partial load.
Maximum hygiene
The minimal water content in relation to the large surface area of the exchanger means that the water is changed several times each day. Legionella does not stand a chance of dangerously multiplying. Large surface areas on heat exchangers necessitate a gentle transfer of heat (no superheated areas). Together with the additional advantages such as ultra-smooth surfaces, short dwell times and turbulence within the fluid, the deposition and accumulation of limescale is massively reduced.
Legionella - not a problem with FRIONIC
Tap water installations are subject to the risk of microorganisms growing inside them. The accumulation of limescale and corrosion provides an ideal surface for microbial activity, particularly legionella. Legionella are bacteria that exist in local bodies of water. Under optimal conditions at temperatures between 25 °C and 50 °C they are able to multiply rapidly. The risk of rapid growth is highest in poorly maintained hot water systems or systems that have not been used for a period of time. Breathing in a spray containing the bacteria, such as when showering, can lead to serious illness, particularly in the elderly and those with weakened immune systems.
All the advantages of the process water exchanger installed in the FRIONIC, but especially the small volume, which is implemented many times a day, do not give Legionnaire bacteria a chance to reproduce in a way that is hazardous to health.
Accessories / Replacement parts
-
Bypass check valve
-
Heating element