These regulators and valves are used where there are high demands on the system for cooled unpackaged foodstuffs, e.g. deli counters, cold storage rooms for meat products, cold storage areas for fruit and vegetables, containers, air conditioning systems, etc. A KVS valve is used, the size of ...
?xml>These regulators and valves are used where there are high demands on the system for cooled unpackaged foodstuffs, e.g. deli counters, cold storage rooms for meat products, cold storage areas for fruit and vegetables, containers, air conditioning systems, etc. A KVS valve is used, the size of which is determined by the cooling capacity requirements. The valve is fully open in the event of an interruption to cooling or power failure. A solenoid valve is built into the fluid line. This closes if the regulator stops cooling. The Sair sensor is placed in the cold air stream after the evaporator. The regulator can be equipped with data communication so that it can be coupled with other devices in ADAP-KOOL® refrigeration system management systems. This enabled operation, monitoring and data collection from a PC - either on site or remote.
Features
- Waste is reduced as humidity in the area around the goods is kept as high as possible
- After levelling out, the temperature is maintained within ±0.5 °C or better
- Levelling is controlled by an adaptive function that minimises temperature fluctuations
- Defrost sensor to keep defrosting periods ...
- Waste is reduced as humidity in the area around the goods is kept as high as possible
- After levelling out, the temperature is maintained within ±0.5 °C or better
- Levelling is controlled by an adaptive function that minimises temperature fluctuations
- Defrost sensor to keep defrosting periods as short as possible
- PID control
- Modulating temperature regulation
- Defrost function, electrical, with hot gas or natural
- Alarm if the set thresholds are exceeded
- Relay output for defrost function, solenoid valve, fan and alarm device
- Input signal that can be used to change the target temperature