- Products
- Refrigeration components
- Refrigerant collectors
- Standing
- Frigomec liquid collector vertical FSR 80.32+2SGR7k+EMd+SV(LA35/RV28) 45bar
Frigomec liquid collector vertical FSR 80.32+2SGR7k+EMd+SV(LA35/RV28) 45bar
Description
Model FSR | standing construction | lower side valve
The refrigerant collectors consist of a jacket and two curved bases that are welded with circular seams. The equipment of the refrigerant collector is variable with regard to the type and arrangement of the connections, sight glasses and ...
Model FSR | standing construction | lower side valve
The refrigerant collectors consist of a jacket and two curved bases that are welded with circular seams. The equipment of the refrigerant collector is variable with regard to the type and arrangement of the connections, sight glasses and accessories. Deviations from the standard or regular equipment must be indicated. The outside of the refrigerant collector is given a surface protection (black), e.g., B. baked-in powder coating or paint. The interior is dried and sealed. Instead of a sight glass, an electronic level control (ESA) can optionally be installed.
Type code
FSR45.27 + 2SG4 + ESA + SV + K (LA28 / RV28)
FSR(1) 45(2) .27(3) + 2SG4(4) + ESA(5) + SV(6) + K(7) (LA28 / RV28)(8)
1. Identification of the series
2. Contents (liters) approximate table of contents (see data sheet)
3. Identification of the jacket diameter (mm):
15 = 159.0
21 = 219.1
27 = ...
FSR45.27 + 2SG4 + ESA + SV + K (LA28 / RV28)
FSR(1) 45(2) .27(3) + 2SG4(4) + ESA(5) + SV(6) + K(7) (LA28 / RV28)(8)
1. Identification of the series
2. Contents (liters) approximate table of contents (see data sheet)
3. Identification of the jacket diameter (mm):
15 = 159.0
21 = 219.1
27 = 273.0
32 = 323.9
40 = 406.4
50 = 508.0
4. Number and type of sight glasses:
SGR 5, SGR 7, SGR 9, SG 4 = one sight glass
2 SGR 7, 2 SGR 9, 2 SG 4 = two sight glasses
3 SGR 7, 3 SGR 9, 3 SG 4 = three sight glasses
5. Level control:
ESA = electronic level control
EM = connection for electronic level control (socket 1 3/4 '' - 12 UN)
6. Connection for safety valve:
SV = threaded socket 1/2 '' - NPT (inside), (on request also 1 1 / 4-12 UNF)
7. K = compressor console
8. Refrigerant inlet / refrigerant outlet:
LA = extinguishing agent adapter with screw connection (Rotalock)
RV = angle valve with screw connection (Rotalock)
M = solder socket
Accessories / Replacement parts
-
Accessories / spare parts
-
Fill-level controls