Panasonic air conditioner outdoor unit VRF 2-wire ECOi EX U-14ME2E8 40KW

Order No.: 758.1439
Manufacturer number: U-14ME2E8
Manufacturer: Panasonic

To previous product 758.1258

More in this category: two pipe system

Loading

One click to the most important information:

Description

The new ECOi EX systems feature outstanding energy efficiency, the highest SEER values and operate extremely efficiently when under partial load. Energy costs can be significantly reduced by using exclusively inverter-controlled high-performance compressors allowing independent and flexible ...

The new ECOi EX systems feature outstanding energy efficiency, the highest SEER values and operate extremely efficiently when under partial load. Energy costs can be significantly reduced by using exclusively inverter-controlled high-performance compressors allowing independent and flexible performance adaptation based on load conditions. The high-performance devices in the ECOi EX series operate extremely reliably even in extreme outdoor temperatures. The tough devices of the ECOi EX series have been designed for an extremely wide operational range: They can operate in cooling mode up to 52 °C and in heating mode down to -25 °C. In cooling mode, they can deliver 100% of the rated cooling performance up to an outdoor temperature of 43 °C.


Please see the Panasonic 2019/20 price list from page 88 onwards to find the right combination of devices or get in touch with the relevant sales location.

show more


Features

  • Outstanding efficiency
  • One or two inverter-controlled double piston compressors per outdoor module
  • Bluefin anti-corrosion coating on heat exchanger fins
  • Improved air flow with newly arranged outlet opening
  • Continuous heat exchanger on three sides of the device
  • Intelligent oil return control
  • High ...
  • Outstanding efficiency
  • One or two inverter-controlled double piston compressors per outdoor module
  • Bluefin anti-corrosion coating on heat exchanger fins
  • Improved air flow with newly arranged outlet opening
  • Continuous heat exchanger on three sides of the device
  • Intelligent oil return control
  • High degree of flexibility for piping
  • Large range of temperatures for cooling and heating operation
  • Maximum height difference of 90 m (optional)

show more


Technical data

Dimensions
Width
1180 mm
Height
1842 mm
Depth
1000 mm
General information
Connectable indoor units
35
Type
VRF
Construction
Außengerät
Refrigerant
R410A
max. connection ratio inside/outside
50 - 130 %
Pressure
External static pressure (low
high)
- / 80 Pa
Electrical Data
Recommended overcurrent relay
3 x 40 A
Supply voltage
400/3/50 V/Ph/Hz
empfohlener Netzkabel­querschnitt
5 x 10 mm²
max. starting current
2 A
max. power consumption
23,40 A
Weight
Weight net
315,0 kg
Performance data
Air volume
Heating (high)
13920 m³/h
Cooling (high)
13920 m³/h
Nominal heating capacity
45,00 kW
Nominal cooling capacity
40,00 kW
Nominal power consumption
Heating
9,86 kW
Cooling
10,30 kW
SCOP
4,28
explanation 2
SEER
7,23
explanation 2
Pipe connections
Liquid line
12,70 mm
1/2 Zoll
 
15,88 mm
5/8 Zoll (Erläuterung 4)
Suction gas line
25,40 mm
1 Zoll
 
28,58 mm
1 1/8 Zoll (Erläuterung 4)
Oil equalization line
6.35 mm
 
1/4 inch
Sound data
Sound pressure level
Heating
60 dB(A)
explanation 3
Schalldruckpegel
Kühlen
60 dB(A)
explanation 3
Sound power
Heating (high)
81 dB(A)
Cooling (high)
81 dB(A)
Temperature data
Außentemperatur-­Grenzwerte
Heizen
-25 bis +18 °C
Kühlen
-10 bis +52 °C

Notes:

  1. EER/COP values calculated in accordance with EN14511.
  2. SEER/SCOP values are calculated according to the specifications in the EU Regulation 2016/2281 and based on the seasonal room cooling/heating energy efficiency (η) with the following formula: SEER, SCOP = (η + correction factor) × primary energy factor.
  3. Measurement location: 1 m in front of the device at a height of 1.5 m. The measured values are based on EUROVENT document 6/C/006-97.
  4. Equivalent distance to furthest indoor units shorter than 90 m / longer than 90 m (if the equalisation length of the longest line is more than 90 m, then the next largest pipe diameter must be selected for both the intake gas and liquid lines).
  5. If the following conditions are met, then a connection ratio of more than 130% to max. 200% is possible: A) the maximum number of indoor units that can be connected in maintained. B) the lower outdoor temperature boundary in heating mode is -10 °C WB (instead of -25 °C WB as with standard connection ratios). C) The simultaneous operation of indoor units is limited to one indoor unit at no more than 130% of the outdoor device power.
Technical modifications reserved. Product images may differ from the actual product and are meant for demonstration purposes only. Absolutely no liability can be assumed for possible indication errors and errors in the manufacturers’ information.

Customers also bought...

Loading

Login now for complete access

To login
Article in stock
Optional article
Panasonic Inbetriebnahme VRF ECOi für 5 bis 10 Innengeräte
Commissioning

Panasonic Inbetriebnahme VRF ECOi für 5 bis 10 Innengeräte

Order No.: D00.0034
Panasonic Inbetriebnahme VRF ECOi für 11 bis 20 Innengeräte
Commissioning

Panasonic Inbetriebnahme VRF ECOi für 11 bis 20 Innengeräte

Order No.: D00.0035
Panasonic Inbetriebnahme VRF ECOi für 21 bis 30 Innengeräte
Commissioning

Panasonic Inbetriebnahme VRF ECOi für 21 bis 30 Innengeräte

Order No.: D00.0041