Wall-mounted units

Panasonic air conditioner PACi wall PK S-100PK2E5B 10kW

Order No.: 758.2170
Manufacturer number: S-100PK2E5B
Manufacturer: Panasonic

To previous product 758.1135
To subsequent product 758.2361

Loading

One click to the most important information:

Description

The PACi wall-mounted units have a wide power range for use in numerous different settings. They are particularly suitable for gyms, exercise rooms, areas with high ceiling and even IT server rooms. The compact size and flat front panel allows the unit to be discreetly installed even in small ...

The PACi wall-mounted units have a wide power range for use in numerous different settings. They are particularly suitable for gyms, exercise rooms, areas with high ceiling and even IT server rooms. The compact size and flat front panel allows the unit to be discreetly installed even in small rooms.

show more


Features

  • Smooth front panel with modern design
  • Elegant and yet tough
  • Elegant matt white colour
  • DC fan motor for improved efficiency
  • Flexible options for connecting refrigerant lines
  • datanavi function available (with optional CZ-RTC5B operating unit)
  • Simple connection to an external ventilation unit or ...
  • Smooth front panel with modern design
  • Elegant and yet tough
  • Elegant matt white colour
  • DC fan motor for improved efficiency
  • Flexible options for connecting refrigerant lines
  • datanavi function available (with optional CZ-RTC5B operating unit)
  • Simple connection to an external ventilation unit or enthalpy heat exchanger (ERV) via PAW-FDC plug connection on the control board of the indoor unit.
  • The outdoor unit can be turned on an off using the remote control for the Panasonic indoor unit
  • Closed air guide slat
  • Low noise operation
  • Flexible installation
  • Airflow automatically adjusted depending on the operating mode.

show more


Suitable products
Outdoor unit Elite 400 V
Panasonic air conditioner outdoor unit PACi elite PZH U-100PZH2E8 10kW 400V R32

Panasonic air conditioner outdoor unit PACi elite PZH U-100PZH2E8 10kW 400V R32

Order No.: 758.2211

Accessories / Replacement parts

  • Design cable remote control
    Panasonic cable remote control PACi/ECOi CZ-RTC5B design cable remote control
    Order No.: 758.2554
  • Hotel remote control
    Panasonic cable remote control PACi/ECOi CZ-RE2C2 hotel remote control
    Order No.: 758.1561
  • Infrared cable remote control
    Panasonic remote control infrared CZ-RWS3 f. WG MK2/PK2 and cassette MY2/PY2
    Order No.: 758.2592
  • PAW-PACR3
    Panasonic communication PACi server PAW-PACR3 redundancy circuit of 2/3 syst.
    Order No.: 758.1608
  • WLAN interface
    Panasonic WLAN adapter for ECOi/PACi CZ-CAPWFC1
    Order No.: 758.2612

Technical data

Dimensions
Width
1120 mm
Height
302 mm
Depth
236 mm
General information
Energy efficiency­class
Heating
A+
Cooling
A++
Weight
Weight net
14,00 kg
Performance data
Design load
Heating
8,00 kW
at -10 °C
Cooling
9,50 kW
COP
3,97
explanation 1
EER
3,26
explanation 1
Annual power consumption
Heating
2732 kWh/a
explanation 3
Cooling
526 kWh/a
explanation 3
Luftmenge
Heizen
(Niedrig/Mittel/Hoch)
900 / 1110 / 1320 m³/h
Kühlen
(Niedrig/Mittel/Hoch)
900 / 1110 / 1320 m³/h
Nominal heating capacity
9,50 kW
Nominal cooling capacity
9,50 kW
Nominal power consumption
Heating
2,39 kW
Cooling
2,91
SCOP
4,10
explanation 2
SEER
6,30
explanation 2
Sound data
Schalldruckpegel
Heizen
(Niedrig/Mittel/Hoch)
41 / 45 / 49 dB(A)
explanation 4
Kühlen
(Niedrig/Mittel/Hoch)
41 / 45 / 49 dB(A)
explanation 4

Notes

  1. EER/COP values calculated according to EN14511. 
  2. SEER/SCOP values are calculated according to EU Regulation 626/2011 for models with a rated power up to 12 kW and EU Regulation 281/2016 for models with a rated power above 12 kW.
  3. The annual power consumption is calculated based on the specifications in EU Regulation 626/2011.
  4. Measurement locations - indoor unit: 1 m in front of and 1 m below the unit. The measured values are based on EUROVENT document 6/C/006-97.
  5. Outdoor unit placed higher than indoor unit. * A fuse of 3 A is recommended for the indoor unit.
  6. Applies in conjunction with outdoor unit at 230 V - small deviation possible with 400 V outdoor unit.
Technical modifications reserved. Product images may differ from the actual product and are meant for demonstration purposes only. Absolutely no liability can be assumed for possible indication errors and errors in the manufacturers’ information.
Loading

Login now for complete access

To login