Concealed duct installation units

Panasonic air conditioner PACi concealed duct unit PF S-50PF1E5B 5.0kW

Order No.: 758.2192
Manufacturer number: S-50PF1E5B
Manufacturer: Panasonic

To previous product 758.1163
To subsequent product 758.2357

Loading

One click to the most important information:

Description

The lightweight, compact and flat design of the unit using galvanised steel is noise and heat insulating. The exceptionally low noise radial fan is directly driven via an electronically controlled DC fan motor. Flexible adjustment of the external static pressure and air volume is either done ...

The lightweight, compact and flat design of the unit using galvanised steel is noise and heat insulating. The exceptionally low noise radial fan is directly driven via an electronically controlled DC fan motor. Flexible adjustment of the external static pressure and air volume is either done manually using the remote control or controlled automatically. The PF duct units are specially designed for applications requiring a fixed rectangular air duct connection. The standard air outlet temperature monitoring prevents streams of cold air and is designed for precise regulation of the room temperature. Air outlet is via a suction-side duct connection. The heat exchanger is made of copper pipes with aluminium fins, condensate drainage system with integrated condensate pump (delivery head from lower edge of unit 785 mm) and safety float switch.

230 V version on request: U-100PZH2E5 758.2209 U-125PZH2E5 U-140PZH2E5

show more


Features

· High external static pressure up to 150 Pa
· Automatic determination and setting of the required static pressure during commissioning (standard wired control panel required)
· DC fan for better energy efficiency
· Integrated condensate pump
· datanavi feature available (with ...

· High external static pressure up to 150 Pa
· Automatic determination and setting of the required static pressure during commissioning (standard wired control panel required)
· DC fan for better energy efficiency
· Integrated condensate pump
· datanavi feature available (with optional control unit CZ-RTC5B)
· Please get in touch to ask about use in dual, trio and quattro systems

show more


Suitable products
Outdoor unit
Panasonic air conditioner outdoor unit PACi elite PZH U-50PZH2E5 5,0kW 230V R32

Panasonic air conditioner outdoor unit PACi elite PZH U-50PZH2E5 5,0kW 230V R32

Order No.: 758.2206

Accessories / Replacement parts

  • Air intake chamber
    Panasonic air intake chamber for MF2 / PF1 ECOi PACi CZ-DUMPA56MF2 concealed duct unit 2.2 -5.6kW
    Order No.: 758.1591
  • Air outlet chamber
    Panasonic air discharge chamber CZ-56DAF2 f. PF/MF concealed duct unit 2.2-5.6kW
    Order No.: 758.1588
  • Design cable remote control
    Panasonic cable remote control PACi/ECOi CZ-RTC5B design cable remote control
    Order No.: 758.2554
  • Hotel remote control
    Panasonic cable remote control PACi/ECOi CZ-RE2C2 hotel remote control
    Order No.: 758.1561
  • Infrared receiver for infrared remote control
    Panasonic receiver f. infrared remote control concealed duct unit CZ-RWRC3 f. ECOi concealed duct unit MM1, MF2
    Order No.: 758.2611
  • Infrared remote control
    Panasonic remote control infrared CZ-RWS3 f. WG MK2/PK2 and cassette MY2/PY2
    Order No.: 758.2592
  • WLAN interface
    Panasonic communication PACi server PAW-PACR3 redundancy circuit of 2/3 syst.
    Order No.: 758.1608

Technical data

Pressure
External static pressure (low
high)
10 / 150 Pa
Electrical Data
Supply voltage
230/1/50 V/Ph/Hz
Performance data
Nominal heating capacity
5,60 kW
Nominal cooling capacity
5,0 kW
Nominal power consumption
Heating
1,24 kW
Cooling
1,20 kW
Sound data
Schalldruckpegel
Heizen
(Niedrig/Mittel/Hoch)
26 / 30 / 33 dB(A)
Kühlen
(Niedrig/Mittel/Hoch)
26 / 30 / 33 dB(A)

Note:

  1. EER / COP values are calculated in accordance with EN14511.
  2. Energy efficiency scale from A+++ to D.
  3. The annual power consumption is based on the standards in EU Regulation 626/2011.
  4. Measurement locations - Indoor unit: 1 m in front of and 80 cm below the unit; outdoor unit: 1 m in front of and behind the unit. The sound level values are based on JIS C 9612. Quiet: Silent running. Low: Lowest configurable fan speed.
  5. 70 mm needs to be added for the pipe connection.
  6. Outdoor unit is placed higher up than the indoor unit.
Technical modifications reserved. Product images may differ from the actual product and are meant for demonstration purposes only. Absolutely no liability can be assumed for possible indication errors and errors in the manufacturers’ information.
Loading

Login now for complete access

To login