- Produkte
- testo 570-2 electronic installation aid complete in case 0563 5702
testo 570-2 electronic installation aid complete in case 0563 5702
One click to the most important information:
Description
The testo 570-2 digital installation aid takes the load off your toolbox - because it replaces many of the tools and measurement devices that you need as part of your day-to-day work on refrigeration systems and heat pumps: It measures, analyses and documents pressure, temperature, current and ...
?xml>The testo 570-2 digital installation aid takes the load off your toolbox - because it replaces many of the tools and measurement devices that you need as part of your day-to-day work on refrigeration systems and heat pumps: It measures, analyses and documents pressure, temperature, current and vacuum measurement values and stores all measurement data from commissioning to service and maintenance through to fault analysis of a system.
The testo 570-2 digital installation aid is very practical with its sturdy 4-way valve block, 4 connections, 4 hose parkers and sight glass. It allows for safe, efficient work during commissioning, service and maintenance.
The stable housing offers reliable protection against impacts, while the suspension mechanism on the back secures the device during measurement. The measurement values can be easily read on the large, illuminated display at all times, even when visibility is poor.
Features
- Measurement value recording over a period of up to 999 hours: The results are safely stored in the device even with long-term measurements on refrigeration systems or heat pumps
- Real-time recording and graphic display of the measurement data: You can optionally purchase the "EasyKool" software, ...
- Measurement value recording over a period of up to 999 hours: The results are safely stored in the device even with long-term measurements on refrigeration systems or heat pumps
- Real-time recording and graphic display of the measurement data: You can optionally purchase the "EasyKool" software, which allows you to prepare the measurement data in a clear format. This is especially helpful for discovering sources of error in case of malfunctions and to take countermeasures if necessary
- Protocol viewing and printing: The optionally available testo high-speed printer facilitates on-site printing of the measurement data. You can also view measurement protocols in the "EasyKool" software (optional)
- Suitable for all conventional refrigerants: The current 40 refrigerants are stored in the installation aid and can be updated using the optional "EasyKool" software when necessary
- Pressure measurement with automatic temperature calculation: The measurement of high and low pressure is carried out via two temperature-compensated pressure sensors, which also calculate the temperatures automatically
- Three connections for external temperature sensors: Connect up to three temperature sensors (optional) to calculate superheating and undercooling in parallel and record the ambient temperature (e.g. in the cold storage facility)
- Integrated vacuum measurement: When evacuating refrigeration systems, the 4-way installation aid can be used to perform vacuum measurements. The integrated vacuum sensor makes precise vacuum measurements possible
- Automatic heat pump mode: Saves the need to replace refrigerant hoses
- Additional features such as the temperature-compensated tightness test and the automatic ambient pressure compensation, which are included in the digital installation aid
Scope of delivery
testo 570-2 digital 4-way installation aid set including two clamp temperature sensors, "EasyKool" PC software (free download), USB data cable, system case, power supply unit, calibration protocol and batteries.
Refrigerant in unit
R12; R123; R1233zd; R1234yf; R134a; R22; R290; R401A; R401B; R402A; R402B; R404A; R407A; R407C; R408A; R409A; R410A; R414B; R416A; R420A; R421A; R421B; R422B; R422D; R424A; R427A; R434A; R437A; R438A; R448A; R449A; R450A; R452A; R455A; R502; R503; R507; R513A; R600a; R718 (H₂O); R744 ...?xml>
R12; R123; R1233zd; R1234yf; R134a; R22; R290; R401A; R401B; R402A; R402B; R404A; R407A; R407C; R408A; R409A; R410A; R414B; R416A; R420A; R421A; R421B; R422B; R422D; R424A; R427A; R434A; R437A; R438A; R448A; R449A; R450A; R452A; R455A; R502; R503; R507; R513A; R600a; R718 (H₂O); R744 (CO₂)
Refrigerants can be updated via software
EasyKool; R11; FX80; I12A; R114; R1150; R1234ze; R124; R125; R1270; R13; R13B1; R14; R142B; R152A; R161; R170; R227; R23; R236fa; R245fa; R32; R401C; R406A; R407B; R407D; R407F; R407H; R41; R411A; R412A; R413A; R417A; R417B; R417C; R422A; R422C; R426A; R442A; R444B; R452B; R453a; R454A; R454B; R454C; R458A; R500; R508A; R508B; R600; RIS89; ...?xml>
EasyKool; R11; FX80; I12A; R114; R1150; R1234ze; R124; R125; R1270; R13; R13B1; R14; R142B; R152A; R161; R170; R227; R23; R236fa; R245fa; R32; R401C; R406A; R407B; R407D; R407F; R407H; R41; R411A; R412A; R413A; R417A; R417B; R417C; R422A; R422C; R426A; R442A; R444B; R452B; R453a; R454A; R454B; R454C; R458A; R500; R508A; R508B; R600; RIS89; SP22
Accessories / Replacement parts
-
Battery
-
Case
-
Clamp sensor
-
Probe / sensor