- Produkte
- Compressors & Assemblies
- Condensing units
- Outdoor units
- Semi-hermetic
- Semi - hermetic
- Bitzer Außeneinheit ECOSTAR Schiessl LHV7E/4CE-9.FY mit Delta P-II montiert
Bitzer Außeneinheit ECOSTAR Schiessl LHV7E/4CE-9.FY mit Delta P-II montiert
More in this category: Semi - hermetic
One click to the most important information:
Description
The scope of delivery includes the Bitzer ECOSTAR LHV7E/4CE-9.F3Y outdoor unit and a Bitzer oil differential pressure switch. You can find further information in the "Scope of delivery" tab
The new generation of ECOSTAR condenser units
The Ecodesign Directive introduced more stringent ...
The scope of delivery includes the Bitzer ECOSTAR LHV7E/4CE-9.F3Y outdoor unit and a Bitzer oil differential pressure switch. You can find further information in the "Scope of delivery" tab
The new generation of ECOSTAR condenser units
The Ecodesign Directive introduced more stringent efficiency requirements for fans and condenser units. The new ECOSTAR condenser units fulfil these criteria.
Cooling performance can be optimally adjusted as needed using the speed regulator for the compressors and fans. The complete set allows for fast and simple onsite assembly without having to spend time installing additional components. The series has now been extended with new models for freezing applications with increased cooling performance.
Speed-controlled fans
- low noise, e.g. time-based activation of low sound mode at night
ECOLINE compressors with integrated suction gas cooled frequency converter
- Extremely reliable
- high system efficiency
- low operating costs
“Plug & Play” with integrated, fully programmable controller, wiring and piping
- Simple onsite installation and configuration
Special features
- more effective EC fans
- reduced noise
- improved condensing efficiency using optimised minichannel compressors
- high efficiency ECOLINE VARISPEED compressors
- robust weatherproof metal casing
Key new features:
Auto emergency operation:
• If the event of a sensor fault, the ECOSTAR condenser unit will not shut off
• As soon as the sensor once again begins reporting correct valves, the ECOSTAR condenser unit switches back to normal operation
External release without alarm:
• The alarm relay can be optionally set to remain deactivated where no external release have been given
Externally controlled night mode:
• Night mode limits the compressor frequency and fan speed in order to reduce noise emissions to no more than 45 dB(A).
For more information on the technical data of the compressor, please click here: Compressor 4CE-9.F3Y-40S - 101.7654
Features
- Higher fan efficiency due to EC fans
- Reduced noise level
- Improved condenser efficiency due to optimized minichannel condenser
- Highly efficient ECOLINE VARISPEED compressors
- Robust metal weatherproof housing
Scope of delivery
- Bitzer semi-hermetic compressor CE3F 4CE-9.F3Y-40S
- High and low pressure switch
- Accessories package
- Weatherproof housing
- Fan: electr. speed controller
- Protective gas filling
- Compressed gas temperature sensor
- Suction gas temperature sensor
- Filter dryer
- Data log
- Bitzer oil ...
- Bitzer semi-hermetic compressor CE3F 4CE-9.F3Y-40S
- High and low pressure switch
- Accessories package
- Weatherproof housing
- Fan: electr. speed controller
- Protective gas filling
- Compressed gas temperature sensor
- Suction gas temperature sensor
- Filter dryer
- Data log
- Bitzer oil differential pressure switch mounted Delta P-II f.condensing units LH..
Accessories / Replacement parts
-
BEST Converter
-
Check valve
-
Coil
-
Display
-
Filter dryer
-
Frequency convertor
-
Fuse
-
Master contactor
-
Master switch
-
Oil differential pressure switch
-
Oil separator
-
Option: Refrigerator oil BSE55, tc > 55 °C
-
Pressure sensor
-
Pressurised gas temperature sensor
-
Refrigerator oil
-
Temperature sensor
-
Transformer
Technical data
Erläuterung
- Andere Spannungen und Stromarten auf Anfrage
380-420 V Y/3/50
- Bei 400V/3/50 Hz Netzspannung
- Daten für maximale Betriebsbedingungen. Lüfter sind drehzahlgeregelt in Abhängigkeit von Betriebsbedingungen.
Effektive Leistungsaufnahme ist deshalb variabel – siehe BITZER Software.