Reciprocating piston
Bock compressor HAX44e/665-4 400V
Icon. Image similar to product.
Icon. Image similar to product.
Icon. Image similar to product.
Description
The HA-System - The best solution for freezing!
- Direct suction with external ventilation
- Suction gas is fed directly into the compressor
- Motor is cooled via an integrated ventilation unit
This results in a reduction in the compressed gas temperature and thus an expansion of the area of application ...
?xml>The HA-System - The best solution for freezing!
- Direct suction with external ventilation
- Suction gas is fed directly into the compressor
- Motor is cooled via an integrated ventilation unit
This results in a reduction in the compressed gas temperature and thus an expansion of the area of application combined with enhanced performance (freezing - R22, R404A). The motor is also spatially separated from the compressor, which is especially beneficial if the motor suffers any damage.
Accessories / Replacement parts
-
DP-Modbus Gateway
-
Intermediate flange
-
Modbus-LAN Gateway
-
Refrigerator oil
-
USB converter
-
Unloaded start system
Technical data
General information
Number of cylinders
4 pcs
Refrigerant
R448A/R449AR407A/F
Type
HAX44e/665-4
Electrical Data
Starting current (locked rotor)
101 / 174 A
(see explanation 1)
Supply voltage
400/3/50 V/Ph/Hz
(see explanation 1)
max. operating current
20,3 A
(see explanation 2)
max. power consumption
11,0 kW
(see explanation 2)
Weight
Weight net
174 kg
Performance data
Flow volume
57,70 m³/h
at 1450 rpm-1
Pipe connections
Pressure line
28 mm
1 1/8 inch
Suction line
35 mm
1 3/8 inch
Volume
Oil charge
ESTER SE55
Oil quantity
2,7 l
Notes
- Tolerance (± 10%) based on the mean voltage range. Other voltages and current types on request All figures based on the mean voltage range.
380-420 V Y/YY-3-50 Hz PW
440-480 V Y/YY-3-60 Hz PW
PW = Part Winding, motors for part winding start
(unloaded start not required)
Y/Δ designs on request.
- - Max. power consumption figures are based on the set power supply.
- Max. operating current / max. power consumption must be observed when selecting contactors, supply cables and fuses.
Contactors: Utilisation category AC3
Technical modifications reserved. Product images may differ from the actual product and are meant for demonstration purposes only. Absolutely no liability can be assumed for possible indication errors and errors in the manufacturers’ information.