- Produkte
- Compressors & Assemblies
- Compressors
- Semi-hermetic
- Reciprocating piston
- Bitzer halbh. Verdichter CE4S m.IQ 44TES-16Y-40P 400V
Bitzer halbh. Verdichter CE4S m.IQ 44TES-16Y-40P 400V
More in this category: Reciprocating piston
One click to the most important information:
Description
Tandem compressors are the simplest type of parallel compressor system using two compressors
Exceptionally effective performance scaling can be achieved by turning a single compressor on and off. The 4 and 6 cylinders models can also be fitted with power regulators (cylinder shut-off) to allow ...
Tandem compressors are the simplest type of parallel compressor system using two compressors
Exceptionally effective performance scaling can be achieved by turning a single compressor on and off. The 4 and 6 cylinders models can also be fitted with power regulators (cylinder shut-off) to allow operation with up to four or six performance levels. Affordable and energy-efficient full and partial load operation is possible using all conventional refrigerants, especially in applications with widely varying loads.
ECOLINE models
This series of tandem compressors use 2-6 cylinder BITZER semi-hermetic compressors, opening a new dimension for simple and compact parallel systems. This is in addition to the usual features of semi-hermetic compressors.
For further information regarding the technical design of the compressors, see single compressors.
Performance data
All values are based on European norm EN 12900 and 50 Hz operation. The evaporation and condensation temperatures refer to dew point values (saturation conditions).
All data is without fluid super-cooling. Based on EN 12900 this data contains significantly different values compared to data acquired from using a 5 or 8.3 K super-cooler.
See refrigerant report (A-500) for explanations.
Power consumption and usage limitations
See KP-104 and BITZER software. Usage limitations are the same as for a single compressor.
Accessories / Replacement parts
-
Additional ventilator
-
Crankcase heater
-
Druckmessumformer
-
IQ-Modul
-
Injector valve
-
Option: Refrigerator oil BSE55 with R134a, tc > 70 °C
-
Pressurised gas temperature sensor
-
Refrigerator oil
-
Ölniveauregulator
-
Ölniveauüberwachung
Technical data
tc > 70 °C
Erläuterungen
1. Daten bezogen auf 400 V/3/50 Hz bei direktem Netzbetrieb. Für die Auslegung von Schützen, Zuleitungen und Sicherungen max. Betriebsstrom / max. Leistungsaufnahme berücksichtigen. Schütze: Gebrauchskategorie AC3. Überstromrelais zur Absicherung des max. Betriebsstroms einsetzen.
Toleranz (±10 %) bezogen auf Mittelwert des Spannungsbereichs. Andere Spannungen und Stromarten auf Anfrage
220-240V Δ/3Ph/50Hz - 380-420V Y/3Ph/50Hz
265-290V Δ/3Ph/60Hz - 440-480V Y/3Ph/60Hz
Daten für die Auslegung des Frequenzumrichters (FU) – Motorversion 3 (R134a Verdichter): bezogen auf 400 V/3/50 Hz Netzspannung und Einsatz des 400 V/3/50 Hz Standardmotors für FU-Betrieb bis 70 Hz. FU mit Motorversion 1 und 2:
Betrieb im gesamten Anwendungsbereich oberhalb 50 Hz erfordert Motor mit Sonderspannung.
Motor für Teilwicklungsanlauf (Part Winding) Y/YY. Wicklungsteilung 50 %/50 %. Ausführung für Y/ auf Anfrage.