- Produkte
- Air conditioners & ventilation systems
- Convectors
- for water
- Wall-mounted units
- Arbonia wall mounted unit Condiline DXA ECM4
Wall-mounted units
Arbonia wall mounted unit Condiline DXA ECM4
Icon. Image similar to product.
Order No.: 778.130127
Manufacturer number: DXA34101185X00A
Manufacturer: Arbonia
More in this category: Wall-mounted units
Loading
One click to the most important information:
Description
DXA wall-mounted unit, space-saving compact unit that runs extremely quietly for use in noise-sensitive areas (bedroom, quiet zones). The DXA wall-mounted unit is optionally available with a 2 or 3-way valve, with Modbus RTU control board or with a remote control. All model variants are ...?xml>
DXA wall-mounted unit, space-saving compact unit that runs extremely quietly for use in noise-sensitive areas (bedroom, quiet zones). The DXA wall-mounted unit is optionally available with a 2 or 3-way valve, with Modbus RTU control board or with a remote control. All model variants are available with a three-phase AC or variable EC motor. Air outlet fins are automatically adjustable on all model variants with a Modbus RTU control board and the variant with remote control. Air outlet fins in housing colour, white (RAL 9003). Housing made of ABS plastic, glossy. The air outlet fins feature moveable intermediate fins that can pivot 30° in either direction to guide the flow of air to the left or right.<br> <br> <br> The following variants can be ordered:<br> <br> DXA ECM / DXA without remote control and without valve<br> DXA ECM-2V / DXA-2V without remote control, with integrated 2-way valve<br> DXA ECM-3V / DXA-3V without remote control, with integrated 3-way valve<br> <br> DXA ECM-T / DXA-T with remote control, without valve<br> DXA ECM-T-2V / DXA-T-2V with remote control and with integrated 2-way valve<br> DXA ECM-T-3V / DXA-T-3V with remote control and integrated 3-way valve<br> <br> DXA ECM-MB / DXA-MB with MB control board, without valve<br> DXA ECM-MB-2V / DXA-MB-2V with MB control board and integrated 2-way valve<br> DXA ECM-MB-3V / DXA-MB-3V with MB control board and integrated 3-way valve<br> <br> <br> All variants can be supplied with integrated heat register. Please ask our technical specialists for performance data.
Features
- 4 sizes with overlengths of 880 and 1185 mm
- Colour RAL 9003
- AC or EC motor technology
- Two or three-way valves
- Double layer system
- Speed level 4 = MAX (speed steps connected in the factory)
- Speed level 2 = MED (speed steps connected in the factory)
- Speed level 1 = MIN (speed steps connected in the ...
- 4 sizes with overlengths of 880 and 1185 mm
- Colour RAL 9003
- AC or EC motor technology
- Two or three-way valves
- Double layer system
- Speed level 4 = MAX (speed steps connected in the factory)
- Speed level 2 = MED (speed steps connected in the factory)
- Speed level 1 = MIN (speed steps connected in the factory)
- Important information about the technical data:
- Acoustic pressure level: In a 100m3 space, reverberation period of 0.5 s, spatial damping factor 9 dB(A)
- Acoustic power level: According to Eurovent
- Air inlet temperature: +27 °C, relative humidity: 50%
- Correction coefficients for other relative humidity values:
- 46%: Total cooling capacity: 0.90
- 46%: Sensitive cooling capacity: 1.00
- 48%: Total cooling capacity: 0.95
- 48%: Sensitive cooling capacity: 1.00
- Water temperature: °C, inlet 7 - outlet 12
Technical data
Dimensions
Width
1185 mm
Height
322 mm
Register size
4
Depth
212 mm
General information
Version
2-Leiter
Type
für Wasser
Construction
Wandgerät
Pressure
Operating pressure
10 bar
Performance data
Inverter control voltage 1 V
Pressure loss water
18,7 kPa
Total cooling capacity
2,50 kW
Air volume
375 m³/h
Sound pressure level
48 dB(A)
Sound power level
57 dB(A)
Sensitive cooling capacity
1,70 kW
Inverter Steuerspannung 1 V
Wasserdurchfluss
431 l/h
Inverter control voltage 10 V
Pressure loss water
44,0 kPa
Total cooling capacity
4,03 kW
Air volume
770 m³/h
Sound pressure level
34 dB(A)
Sound power level
43 dB(A)
Sensitive cooling capacity
2,88 kW
Inverter Steuerspannung 10 V
Wasserdurchfluss
693 l/h
Inverter control voltage 3 V
Pressure loss water
24,5 kPa
Total cooling capacity
2,91 kW
Air volume
465 m³/h
Sound pressure level
44 dB(A)
Sound power level
53 dB(A)
Sensitive cooling capacity
2,00 kW
Inverter Steuerspannung 3 V
Wasserdurchfluss
501 l/h
Inverter control voltage 5 V
Pressure loss water
30,1 kPa
Total cooling capacity
3,26 kW
Air volume
550 m³/h
Sound pressure level
40 dB(A)
Sound power level
49 dB(A)
Sensitive cooling capacity
2,27 kW
Inverter Steuerspannung 5 V
Wasserdurchfluss
562 l/h
Inverter control voltage 7.5 V
Pressure loss water
37,5 kPa
Total cooling capacity
3,69 kW
Air volume
665 m³/h
Sound pressure level
37 dB(A)
Sound power level
46 dB(A)
Sensitive cooling capacity
2,60 kW
Inverter Steuerspannung 7,5 V
Wasserdurchfluss
634 l/h
Nominal cooling capacity
3,26 kW
Inverter Steuerspannung 5 V (mittel)
Temperature data
Media temperature
6 bis 70 °C
Fan data
Fan motor
EC
Technical modifications reserved. Product images may differ from the actual product and are meant for demonstration purposes only. Absolutely no liability can be assumed for possible indication errors and errors in the manufacturers’ information.
Loading