- Produkte
- Panasonic air conditioner PACi concealed duct unit PF S-36PF1E5B 3.6kW
Panasonic air conditioner PACi concealed duct unit PF S-36PF1E5B 3.6kW
One click to the most important information:
Description
The lightweight, compact and flat design of the unit using galvanised steel is noise and heat insulating. The exceptionally low noise radial fan is directly driven via an electronically controlled DC fan motor. Flexible adjustment of the external static pressure and air volume is either done ...
?xml>The lightweight, compact and flat design of the unit using galvanised steel is noise and heat insulating. The exceptionally low noise radial fan is directly driven via an electronically controlled DC fan motor. Flexible adjustment of the external static pressure and air volume is either done manually using the remote control or controlled automatically. The PF duct units are specially designed for applications requiring a fixed rectangular air duct connection. The standard air outlet temperature monitoring prevents streams of cold air and is designed for precise regulation of the room temperature. Air outlet is via a suction-side duct connection. The heat exchanger is made of copper pipes with aluminium fins, condensate drainage system with integrated condensate pump (delivery head from lower edge of unit 785 mm) and safety float switch.
230 V version on request: U-100PZH2E5 758.2209 U-125PZH2E5 U-140PZH2E5
Features
· High external static pressure up to 150 Pa
· Automatic determination and setting of the required static pressure during commissioning (standard wired control panel required)
· DC fan for better energy efficiency
· Integrated condensate pump
· datanavi feature available (with ...
· High external static pressure up to 150 Pa
· Automatic determination and setting of the required static pressure during commissioning (standard wired control panel required)
· DC fan for better energy efficiency
· Integrated condensate pump
· datanavi feature available (with optional control unit CZ-RTC5B)
· Please get in touch to ask about use in dual, trio and quattro systems
Accessories / Replacement parts
-
Air intake chamber
-
Hotel remote control
Technical data
(Niedrig/Mittel/Hoch)
(Niedrig/Mittel/Hoch)
(Flüster/Niedrig/Hoch)
Note:
- EER / COP values are calculated in accordance with EN14511.
- Energy efficiency scale from A+++ to D.
- The annual power consumption is based on the standards in EU Regulation 626/2011.
- Measurement locations - Indoor unit: 1 m in front of and 80 cm below the unit; outdoor unit: 1 m in front of and behind the unit. The sound level values are based on JIS C 9612. Quiet: Silent running. Low: Lowest configurable fan speed.
- 70 mm needs to be added for the pipe connection.
- Outdoor unit is placed higher up than the indoor unit.